Wednesday, September 18, 2019

EIT MC-2A UV Radiometer DataReader Ultraviolet Illuminance Measuring Instrument

EIT MC-2A UV Radiometer DateReader, this type of UVA UV Intensity Meter is specifically for some space to detect the narrow place.The sensor part of the ultraviolet detection instrument in the market is relatively large, which is suitable for measuring the ultraviolet illumination on the conveyor belt with a spacious area. However, it is difficult to measure the ultraviolet illumination value in some narrow places exposed to ultraviolet radiation.

Features of Mini LED UV Measurement for Measuring UV Wavelength
• Small Size: 1.3” x 0.95” x 0.25”
• Lightweight: 0.33 ounces
• Measures total energy density in Joules/cm2
• Measures peak power density in Watts/cm2
• Battery powered
• High sample rate: 2000 Samples per second
• Automatic operation
• High temperature resistance

High Specification Sensors for UV Measurement Exporters

Applications of UVA Light Meters for Sale for Measuring UV Wavelength Importers
• UV systems requiring small size and automatic operation
• Small container curing (bottles, cans, etc.)
• Three-dimensional objects
• Web printing
• Very small conveyorized and batch applications (semiconductor printing, small part bonders, etc.)
• Statistical Process Control measurements

Specification of Personalized UVA UV Integral Sensor Detector for UV Measurement
Spectral Response
UVA (320-390nm, 10% power points)
Sample rate
2000 per second
Total Energy
0 to 9999 Joules/cm2
Resolution
0.001 Joules/cm2
Accuracy
+/- 7% typical @ 25, -0.2% per  over operating range
Peak UV Irradiance
Low Power (-2 Version): 100mW/cm2 to 2W/cm2
High Power (-10 Version): 500mW/cm2 to 10W/cm
Spatial Response
Cosine approximation
Operating Temperature Range
15-70 internal
Time-out Period
Approximately 4 minutes after last UV exposure
Batteries
Permanent lithium cell
MicroCure® Radiometer Life
200 readings or 1 year , whichever comes first
Dimensions
1.30” long x 0.95” wide x 0.25 thick (33.00mm x 24.13mm x 6.35mm)
Weight
0.33oz (9.4 grams)
Materials
Plated Aluminum, nylon

MICROCURE® DATA-READER
User Interface
Push button switches allow user to display total energy and peak UV irradiance or
to reset the unit
Dimensions
5.77” long x 4.38” wide x 1.45” high (146.56mm x 111.25mm x 36.83mm)
Weight
11.75 oz (333.11 grams)
Display
4 digit LCD, programmable decimal point
Operating Temperature Range
0-70
Timeout
30 seconds
Package Material
Steel, nylon, polycarbonate
Battery
One user replaceable 9V lithium battery; 36,000 readings or 5 years 
Specifications are subject to change without notice.

Cheap Accumulated UVA UV Sensor Probe for UV Measurement

Operation of UV Light Meters Detector for Measuring UV Wavelength
The MicroCure® radiometer is designed to be placed in a UV curing environment so that the UV radiation strikes the radiometer in the same manner as it would strike an actual work piece. The radiometer is designed so that when UV strikes the measuring face of the instrument, it automatically measures and stores electronically the amount of UV energy impinged upon it and the peak UV irradiance. Upon completion of the measurement, the operator places the radiometer in a stand-alone Data-Reader. Depressing the “Select” button on the Data-Reader downloads the information in the radiometer and displays on an LCD the total UV energy and peak UV irradiance seen by the radiometer. A short push of the “Select” button toggles between the dosage and UV irradiance measurement readings. Pressing the “Reset” button on the Data-Reader will clear the electronic storage in the radiometer and the readings on the Data-Reader display. The radiometer is now ready to take another reading.

If no UV radiation above a threshold value is encountered for four minutes, the radiometer will enter a “deep sleep” mode. In the “sleep” mode, the radiometer batteries will last a minimum of one year. Alternatively, the unit can make 200 measurements on the same battery.

To ensure that the radiometer battery has sufficient remaining energy, the Data-Reader display indicates how many readings have been made by the individual radiometer since new.

The Data-Reader is battery powered and can perform 36,000 readings on a single battery. A low battery condition is indicated on the display.

Handling and Safety Precautions of Portable Mini UV Light Meters UV Detector
Due to the radiometer's data transfer, case configuration, and the applications for which it was designed, the following precautions should be observed to ensure the radiometer's performance.
• Avoid conductive materials, including process chemicals, process vapors, and anti-static mists when handling the MicroCure®. These materials may cause the unit to short, reset and lose stored data.
• Handling the MicroCure® with gloves reduces the chances of a short occurring.
• Do not let the MicroCure® Best Ultraviolet Radiometer travel through print stations, die cutters, pinch rollers or other processes which may damage both the radiometers and your equipment.
• Do not short the two case sides of a MicroCure® together. Doing so will reset the unit and any stored data will be lost.
• Do not allow MicroCure® radiometers to touch each other. Data loss or corruption may occur.
• Do not mark or label the MicroCure® radiometer case.

Sale UVA Ultraviolet Index for UV Measurement for Sale

Thursday, September 5, 2019

265nm UVC UV LED 3535 Package Deep Ultraviolet Light Sterilization Lamp

265nm UVC Ultraviolet Lights for Sterilization is silicone lens, with the highest sterilization efficiency, widely used in life, medical treatment and industry.

Parameters of High Power UV Chips for Disinfection :
Ceramic patch package with quartz lens
Size : L*W*H 3.5*3.5*1.62 mm
Forward current : up to 150mA
Radiant power : 10mW at 150mA
Lead / terminal finish : gold plated (AU)
Wavelength : 265nm-275nm
Luminous power : 10mW
Electricity : 150mA
Voltage : 6-9V
Angle : 120°

Applications of High Efficiency  265nm UVC UV LED for Disinfection :
High Power 265nm UVC UV LED Lights for Disinfection
High Efficiency 265nm UVC UV LED for UV Flashlight
High Efficiency 265nm UVC UV-LED for Sterilization
Mini UVC UV Light Emitting Diode for Sterilization

For detailed instructions, please click here to download : UVC 265nm UV LED

Best 265nm UVC Ultraviolet LEDs for UV Flashlight Suppliers
High Power 265nm UVC UV LED Lights for Disinfection Wholesalers
Best Price 265nm UVC UV LED for Purification Distributors
High Efficecncy 265nm UVC Ultraviolet LEDs for Sterilization Best Price in the Market
Precautions for use : once welded, never return.
Best Price 265nm UVC Ultraviolet LED for Sterilization
1.Do not directly touch or operate the surface of the silica gel lens, which may damage the internal circuit.
2.Do not stack PCB boards containing LED components. Applying to silicone lenses may cause damage.
3.Lamp beads bust be heat dissipation treatment in use, or it will cause serious damage to LED.

At present, the luminous efficiency of deep ultraviolet LED is less than 5%, and most of the electric energy is converted to heat energy. Heat dissipation must be done well in use, or it will burn out. Constant current drive is recommended.

Specification Parameters of Mini UVC UV Light Emitting Diode :
275nm UVC UV Light Emitting Diode Supplier